Slide 13
The overall structure modeling and analysis are performed using Midas Civil, finite element analysis (FEA) software.
From the concrete collar structural analysis, it could be learned that the most critical engineering parts are not concrete structure integrity such as bending moment, shear stress, and crack is not critical, but the bolts combining each parts of the collar and rubber part making the gap between the pipe and concrete is hot issue to keep the location of collar along the pipeline no movement as well during installation as after installation.
We have covered the design and engineering work for PE pipeline so far, and from now on, I’d like to introduce the installation experience of pipeline from manufacturing to monitoring.
Slide 13
The overall structure modeling and analysis are performed by using Midas Civil, finite element analysis (FEA) software.
From the concrete collar structural analysis, it could be learned that the most critical engineering parts are not the concrete structure integrity such as bending moment and shear stress. Crack is not critical, but the bolts combining each parts of the collar and rubber part making the gap between the pipe and concrete are hot issues to keep the location of collar along the pipeline with no movement as well during installation and after installation.
We have covered the design and engineering work for PE pipeline so far, and (from) now (on), I’d like to introduce the installation experience of pipeline from manufacturing to monitoring.
|